STG Air Curtain to ensure an optimized distribution of combustion air for block type regenerators without partition walls

 

STG Compressed Air Baffles for control of combustion air  
orking principle of STG Compressed Air Baffles

STG Compressed Air Baffles for control of combustion air

If you operate a cross fired furnace controlling the optimum ratio of combustion air for the furnace “in average” it is not enough – you must be able to do it individually port by port. Even if the separating walls between the regenerator chambers are missing, STG’s Air Curtain system, using compressed air baffles, is able to provide individual control to optimize the combustion air distribution. By creating an adjustable barrier of compressed air, parts of the preheated air from the port having excess air will be redirected to the neighbouring ports.

This is recommended for use with Lambda control if no separating walls are available.

Residual Oxygen without Air Curtain

Residual Oxygen with Air Curtain

 

 